JX6Z-9350-A
BOSCH JX6Z-9350-A Vysokotlaké Čerpadlo Ford Focus Mk4 Kuga Escape 1.5T Dragon
JX6G-9D376-AA, GDP110--200 barTechnické specifikace
| Parametr | Hodnota |
|---|---|
| Part Number / SKU | JX6Z-9350-A |
| Manufacturer Brand | BOSCH |
| Component Type | Mechanical High Pressure Fuel Pump (HPFP) |
| Engine Application | Ford 1.5L EcoBoost Dragon Ti-VCT Turbocharged DOHC 12V I3 |
| Provozní tlakKlíčový parametr | |
| Mounting Torque (Flange / Bracket) | 12 N-m (106 lb-in) |
| Fuel Line / Rail Torque | 28 N-m (21 lb-ft) |
| Typické chybové kódy | P0087, P0088, P0171, P0191 |
Kompatibilní vysokotlaké čerpadlo (Sestava palivového okruhu)
Pracuje na stejném vysokotlakém okruhu Common Rail. Při poklesu tlaku (P0087) ověřte dodávku čerpadla před výměnou vstřikovačů.
Pokyny k montáži
- Depressurize Fuel System: Pull fuel pump fuse or disconnect LPFP harness. Crank engine 5-8 seconds until it stalls to drop residual rail pressure below 5 bar.
- Clean Surrounding Cavity: Blow compressed air around cylinder head bore or pump flange cavity to prevent dirt ingress into the fuel rail.
- Lubricate & Fit Seals: Inspect Teflon combustion seals or O-rings. Coat lightly with clean motor oil (do not use grease) to avoid tearing during insertion.
- Torque to Factory Specification: Hand-thread bolts evenly. Tighten mounting fasteners to 12 N-m (106 lb-in), and torque fuel line fittings to 28 N-m (21 lb-ft).
- Prime & Leak Check: Cycle ignition to RUN position 3 times (5 seconds each) to build low-side pressure. Inspect fittings for leaks before starting engine.
Chybove kody (DTC) a diagnosticke protokoly
Bezne diagnosticke chybove kody (DTC), ktere se spousteji pri opotrebeni, zavade obvodu nebo odchylce kalibrace tohoto vstrikovace common rail:
Fuel Rail / System Pressure Too Low
Excessive internal backleak from worn control valve seats drops common rail pressure below target under engine load.
Injector Circuit Malfunction / Open Circuit
Solenoid coil resistance drift (0.2-0.5 Ω) or piezo stack degradation triggers driver stage shutdown on affected cylinders.
Cylinder Misfire & Balancing Deviation
Carbon-clogged nozzle spray holes or missing IMA calibration causes uneven cylinder contribution. Recode ECM and verify washer seating.
Fuel Rail / System Pressure Too High
Spill line backpressure or stuck metering valve prevents rail depressurization, creating overpressure risks under load.
Technické diagnostické a servisní protokoly
Ověřené dílenské postupy, mezní hodnoty testů a servisní postupy pro tento díl.